Uyilo oluguquguqukayo lweeswitshi ze-GREYHOUND 105/106 lwenza esi sixhobo senethiwekhi esinokumelana nexesha elizayo esinokutshintsha kunye neemfuno zombane zenethiwekhi yakho. Ngokugxila ekufumanekeni kwenethiwekhi ephezulu phantsi kweemeko zoshishino, ezi switshi zikuvumela ukuba ukhethe inani lezibuko zesixhobo kunye nohlobo lwazo - zide zikunike amandla okusebenzisa uthotho lwe-GREYHOUND 105/106 njengeswitshi yomqolo.
Iinkcukacha zeMveliso
Iithegi zeMveliso
Umhla woRhwebo
Imveliso inkcazo
| Uhlobo | GRS105-16TX/14SFP-2HV-2A (Ikhowudi yemveliso: GRS105-6F8F16TSGGY9HHSE2A99XX.X.XX) |
| Inkcazo | Uthotho lweGREYHOUND 105/106, iManaged Industrial Switch, uyilo olungenafeni, i-rack mount eyi-19", ngokwe-IEEE 802.3, uyilo lwe-6x1/2.5GE +8xGE +16xGE |
| Inguqulelo yeSoftware | I-HiOS 9.4.01 |
| Inombolo yendawo | 942 287 005 |
| Uhlobo lwezibuko kunye nobungakanani | Iiports ezingama-30 zizonke, i-slot ye-GE/2.5GE SFP eyi-6x + i-slot ye-GE SFP eyi-8x + iiports ze-FE/GE TX eziyi-16x |
Kaninzi Ujongano
| Umbane/unxibelelwano lokubonisa | Igalelo lombane 1: Iplagi ye-IEC, Unxibelelwano lwesignali: Ibhloko yesiphelo seplagi yeepin ezi-2, Igalelo lombane 2: Iplagi ye-IEC |
| Isithuba sekhadi le-SD | Isithuba sekhadi le-SD eli-1 ukuqhagamshela iadaptha yokumisela ngokuzenzekelayo i-ACA31 |
| I-USB-C | 1 x USB-C (umthengi) yolawulo lwengingqi |
Inethiwekhi ubungakanani - ubude of intambo
| Isibini esijijekileyo (TP) | 0-100 m |
| Ifayibha yemowudi enye (SM) 9/125 µm | jonga iimodyuli ze-SFP |
| Ifayibha yemowudi enye (LH) 9/125 µm (i-transceiver yokuthutha ixesha elide) | jonga iimodyuli ze-SFP |
| Ifayibha ye-Multimode (MM) 50/125 µm | jonga iimodyuli ze-SFP |
| Ifayibha ye-Multimode (MM) 62.5/125 µm | jonga iimodyuli ze-SFP |
Inethiwekhi ubungakanani - ukucasuka
| I-topology yomgca / inkwenkwezi | nayiphi na |
Amandla iimfuno
| I-Voltage yokusebenza | Igalelo lombane 1: 110 - 240 VAC, 50 Hz - 60 Hz, Igalelo lombane 2: 110 - 240 VAC, 50 Hz - 60 Hz |
| Ukutya umbane | Iyunithi esisiseko enombane omnye ophezulu. 35W |
| Ukuphuma kwamandla kwi-BTU (IT)/h | ubuninzi. 120 |
Isoftware
|
Ukutshintsha | Ukufunda kwe-VLAN okuZimeleyo, Ukuguga Okukhawulezayo, Ii-Static Unicast/Multicast Address Entries, I-QoS / Port Prioritization (802.1D/p), I-TOS/DSCP Prioritization, I-Interface Trust Mode, Ulawulo lwe-CoS Queue, Ukubumba i-Queue / Max. Queue Bandwidth, Ulawulo lokuhamba (802.3X), Ukubumba i-Egress Interface, Ukhuseleko lwe-Ingress Storm, Ii-Jumbo Frames, I-VLAN (802.1Q), I-VLAN Unware Mode, I-GARP VLAN Registration Protocol (GVRP), I-Voice VLAN, I-GARP Multicast Registration Protocol (GMRP), I-IGMP Snooping/Querier nge-VLAN (v1/v2/v3), Ukucoca i-Multicast engaziwayo, I-Multiple VLAN Registration Protocol (MVRP), I-Multiple MAC Registration Protocol (MMRP), I-Multiple Registration Protocol (MRP), I-IP Ingress DiffServ Classification and Policing, I-IP Egress DiffServ Classification and Policing, I-VLAN esekelwe kwi-Protocol, I-MAC-based VLAN, I-IP subnet-based VLAN, I-Double VLAN Tagging |
| Ukuphinda kusetyenziswe imali engakumbi | I-HIPER-Ring (iRing Switch), iLink Aggregation ne-LACP, iLink Backup, iMedia Redundancy Protocol (MRP) (IEC62439-2), iRSTP 802.1D-2004 (IEC62439-1), iiRSTP Guards |
| Ulawulo | Inkxaso yoMfanekiso weSoftware ezimbini, iTFTP, iSFTP, iSCP, iLLDP (802.1AB), iLLDP-MED, iSSHv2, iHTTP, iHTTPS, uLawulo lwe-IPv6, iiTraps, iSNMP v1/v2/v3, iTelnet, uMthengi weDNS, iSeva ye-OPC-UA |
| Uxilongo | Ulawulo lweDilesi yokuQondwa kweNgxabano, Isaziso seMAC, Uqhagamshelwano lweSignali, Isalathisi seMeko yeSixhobo, i-TCPDump, ii-LED, i-Syslog, ukuGcina i-ACA rhoqo, ukuJonga iPort ngokuZikhubaza ngokuzenzekelayo, ukuQonda iLink Flap, ukuQonda iOverload, ukuQonda iDuplex mismatch, iLink Speed kunye nokuJonga iDuplex, i-RMON (1,2,3,9), iPort Mirroring 1:1, iPort Mirroring 8:1, iPort Mirroring N:1, iPort Mirroring N:2, Ulwazi lweNkqubo, ukuZivavanya kwiCold Start, uVavanyo lweCopper Cable, uLawulo lwe-SFP, iConfiguration Check Dialog, iSwitch Dump, i-imeyile Isaziso, i-RSPAN, i-SFLOW, iVLAN Mirroring |
| Uqwalaselo | Uhlengahlengiso Loqwalaselo Oluzenzekelayo (ukujika umva), Uqwalaselo lweminwe yoqwalaselo, Ifayile yoqwalaselo olusekwe kumbhalo (XML), Uqwalaselo lwe-backup kwiseva ekude xa ugcina, Cima uqwalaselo kodwa ugcine useto lwe-IP, Iklayenti le-BOOTP/DHCP elinoqwalaselo oluzenzekelayo, Iseva ye-DHCP: ngePort, Iseva ye-DHCP: IiPools nge-VLAN, I-AutoConfiguration Adapter ACA31 (ikhadi le-SD), i-HiDiscovery, i-DHCP Relay ene-Option 82, i-Command Line Interface (CLI), i-CLI Scripting, ukuphathwa kweskripthi se-CLI phezu kwe-ENVM xa iqalisa, Inkxaso ye-MIB epheleleyo, Uncedo olusengqiqweni komxholo, Ulawulo olusekwe kwi-HTML5 |
|
Ukhuseleko | Ukhuseleko lweZibuko olusekwe kwi-MAC, Ulawulo lokufikelela olusekwe kwiZibuko olune-802.1X, i-VLAN yeNdwendwe/engaqinisekiswanga, iSeva yoQinisekiso oluDibeneyo (i-IAS), i-RADIUS VLAN Assignment, uThintelo lokuNqanda iNkonzo, i-ACL esekwe kwi-VLAN, i-ACL esekwe kwi-VLAN, i-ACL esisiseko, ukufikelela kuLawulo oluthintelweyo yi-VLAN, iSiboniso soKhuseleko lweSixhobo, uMzila woVavanyo, ukuLoga kwe-CLI, uLawulo lweSatifikethi se-HTTPS, ukufikelela kuLawulo oluNqamlelweyo, iBhana yoSetyenziso olufanelekileyo, uMgaqo-nkqubo wePhasiwedi oCwangcisiweyo, Inani eliQokelelweyo lemizamo yokungena, ukuLoga kwe-SNMP, amanqanaba amaninzi amalungelo, uLawulo lwaBasebenzisi beNdawo, uQinisekiso olukude nge-RADIUS, ukuLoga kwiAkhawunti yoMsebenzisi, utshintsho lwegama eligqithisiweyo ekungeneni kokuqala, i-RADIUS Policy Assignment, uQinisekiso lwabathengi abaninzi ngeZibuko ngalinye, i-MAC Authentication Bypass, iinketho zefomathi ye-MAC authentication bypass, i-DHCP Snooping, i-IP Source Guard, i-Dynamic ARP Inspection, i-LDAP, i-ACL esekwe kwi-MAC, i-ACL esekwe kwi-MAC, i-ACL esekwe kwi-MAC, i-ACL esekwe kwi-IPv4, i-ACL esekwe kwi-IPv4, i-ACL esekwe kwiXesha, i-ACL esekwe kwi-VLAN Ukunciphisa i-ACL, i-ACL flow-based Limits |
| Ukuvumelanisa ixesha | I-PTPv2 Transparent Clock enamanyathelo amabini, I-PTPv2 Boundary Clock, BC ene-Sync ukuya kuthi ga kwi-8 / s, I-Buffered Real Time Client, i-SNTP Client, i-SNTP Server |
| Iiprofayili zeShishini | Iprotokholi ye-Ethernet/IP Modbus TCP PROFINET Protokholi |
| Ezininzi | Ukuwela iintambo ngesandla, umbane wezibuko uphantsi |
Iimeko zemozulu
| Ubushushu bokusebenza | -10 - +60 |
| Phawula | 1 013 941 |
| Ubushushu bokugcina/bokuthutha | -20 - +70 °C |
| Ukufuma okuthelekisekayo (okungavuthisi) | 5-90% |
Ukwakhiwa koomatshini
| Ubukhulu (i-WxHxD) | 444 x 44 x 355 mm |
| Ubunzima | Kuqikelelwa i-5 kg |
| Ukufakelwa | Indawo yokuxhoma irekhi |
| Udidi lokhuseleko | IP30 |
Iimodeli zeHirschmann GRS 105 106 Series GREYHOUND Switch ezikhoyo
GRS105-16TX/14SFP-2HV-3AUR
GRS105-24TX/6SFP-1HV-2A
GRS105-24TX/6SFP-2HV-2A
GRS105-24TX/6SFP-2HV-3AUR
GRS106-16TX/14SFP-1HV-2A
GRS106-16TX/14SFP-2HV-2A
GRS106-16TX/14SFP-2HV-3AUR
GRS106-24TX/6SFP-1HV-2A
GRS106-24TX/6SFP-2HV-2A
GRS106-24TX/6SFP-2HV-3AUR
Iimveliso ezinxulumene noko
-
I-Hirschmann RS20-0400M2M2SDAEHH iSwitch eLawulwayo
Inkcazo Imveliso: RS20-0400M2M2SDAE Isicwangcisi: RS20-0400M2M2SDAE Inkcazo yemveliso Inkcazo I-Fast-Ethernet-Switch eLawulwayo yokuguqula i-DIN rail store-and-forward-switching, uyilo olungenafeni; I-Software Layer 2 Enhanced Part Number 943434001 Uhlobo lwePort kunye nobungakanani Iiports ezi-4 zizonke: 2 x standard 10/100 BASE TX, RJ45; Uplink 1: 1 x 100BASE-FX, MM-SC; Uplink 2: 1 x 100BASE-FX, MM-SC Iimfuno zamandla Osebenza...
-
Hirschmann OCTOPUS-5TX EEC Supply Voltage 24 VD...
Intshayelelo I-OCTOPUS-5TX EEC yiswitshi ye-IP 65 / IP 67 engalawulwayo ngokuhambelana ne-IEEE 802.3, iswitshi yokugcina nokudlulisa, ii-ports ze-Fast-Ethernet (10/100 MBit/s), ii-ports ze-electrical Fast-Ethernet (10/100 MBit/s) M12 Inkcazo yemveliso Uhlobo lwe-OCTOPUS 5TX EEC Inkcazo Iiswitshi ze-OCTOPUS zilungele ukusetyenziswa kwangaphandle...
-
Umphathi oQhelekileyo weHirschmann RS20-2400M2M2SDAEHC/HH...
Inkcazo Inkcazo yemveliso Inkcazo I-Fast-Ethernet-Switch eLawulwayo yoyilo lwe-DIN rail-store-and-forward-switching, i-fanless; I-Software Layer 2 Enhanced Part Number 943434043 Ukufumaneka Umhla wokugqibela we-oda: Disemba 31, 2023 Uhlobo lwezibuko kunye nobungakanani Ii-port ezingama-24 zizonke: 22 x standard 10/100 BASE TX, RJ45; Uplink 1: 1 x 100BASE-FX, MM-SC; Uplink 2: 1 x 100BASE-FX, MM-SC Okunye Unxibelelwano Umbane/uphawu luyaqhubeka...
-
Iswitshi yeHirscnmann RS20-2400S2S2SDAE
Umhla woRhwebo Inkcazo yemveliso Inkcazo I-Fast-Ethernet-Switch eLawulwayo yoyilo lwe-DIN rail-store-and-forward-switching, i-fanless; I-Software Layer 2 Enhanced Part Number 943434045 Uhlobo lwePort kunye nobungakanani Iiports ezingama-24 zizonke: 22 x standard 10/100 BASE TX, RJ45; Uplink 1: 1 x 100BASE-FX, SM-SC; Uplink 2: 1 x 100BASE-FX, SM-SC Okungakumbi Ii-Interfaces Umbane/uphawu loqhagamshelwano 1 x plug-in terminal block, 6-pin V.24 in...
-
IHirschmann SPIDER-SL-20-04T1M29999SZ9HHHH Unman...
Inkcazo yemveliso Imveliso: Hirschmann SPIDER-SL-20-04T1M29999SZ9HHHH Isicwangcisi: SPIDER-SL-20-04T1M29999SZ9HHHH Inkcazo yemveliso Inkcazo Ayilawulwa, Iswitshi sesitimela se-Ethernet yezeMveliso, uyilo olungenafeni, imo yokugcina kunye nokutshintsha phambili, I-Ethernet ekhawulezayo, Uhlobo lwePort ye-Ethernet ekhawulezayo kunye nobungakanani obuyi-4 x 10/100BASE-TX, intambo ye-TP, amasokhethi e-RJ45, ukunqumla ngokuzenzekelayo, ukuxoxisana ngokuzenzekelayo, i-auto-polarity 10/100BASE-TX, intambo ye-TP, amasokhethi e-RJ45, i-au...
-
I-Hirschmann OCTOPUS 16M eLawulwayo ye-IP67 Switch 16 P...
Inkcazo Inkcazo yemveliso Uhlobo: OCTOPUS 16M Inkcazo: Iiswitshi ze-OCTOPUS zilungele ukusetyenziswa ngaphandle kweemeko zokusingqongileyo ezinzima. Ngenxa yemvume eqhelekileyo yesebe, zingasetyenziswa kwizicelo zothutho (E1), kunye noololiwe (EN 50155) kunye neenqanawa (GL). Inombolo yeCandelo: 943912001 Ukufumaneka: Umhla wokugqibela we-odolo: Disemba 31, 2023 Uhlobo lwezibuko kunye nobungakanani: iizibuko ezili-16 kwiizibuko ze-uplink zizonke: 10/10...