Iswitshi yeHirschmann GRS105-16TX/14SFP-2HV-2A
Inkcazo emfutshane:
Uyilo oluguquguqukayo lweeswitshi ze-GREYHOUND 105/106 lwenza esi sixhobo senethiwekhi esinokumelana nexesha elizayo esinokutshintsha kunye neemfuno zombane zenethiwekhi yakho. Ngokugxila ekufumanekeni kwenethiwekhi ephezulu phantsi kweemeko zoshishino, ezi switshi zikuvumela ukuba ukhethe inani lezibuko zesixhobo kunye nohlobo lwazo - zide zikunike amandla okusebenzisa uthotho lwe-GREYHOUND 105/106 njengeswitshi yomqolo.
Iinkcukacha zeMveliso
Iithegi zeMveliso
Umhla woRhwebo
Imveliso inkcazo
| Uhlobo | GRS105-16TX/14SFP-2HV-2A (Ikhowudi yemveliso: GRS105-6F8F16TSGGY9HHSE2A99XX.X.XX) |
| Inkcazo | Uthotho lweGREYHOUND 105/106, iManaged Industrial Switch, uyilo olungenafeni, i-rack mount eyi-19", ngokwe-IEEE 802.3, uyilo lwe-6x1/2.5GE +8xGE +16xGE |
| Inguqulelo yeSoftware | I-HiOS 9.4.01 |
| Inombolo yendawo | 942 287 005 |
| Uhlobo lwezibuko kunye nobungakanani | Iiports ezingama-30 zizonke, i-slot ye-GE/2.5GE SFP eyi-6x + i-slot ye-GE SFP eyi-8x + iiports ze-FE/GE TX eziyi-16x |
Kaninzi Ujongano
| Umbane/unxibelelwano lokubonisa | Igalelo lombane 1: Iplagi ye-IEC, Unxibelelwano lwesignali: Ibhloko yesiphelo seplagi yeepin ezi-2, Igalelo lombane 2: Iplagi ye-IEC |
| Isithuba sekhadi le-SD | Isithuba sekhadi le-SD eli-1 ukuqhagamshela iadaptha yokumisela ngokuzenzekelayo i-ACA31 |
| I-USB-C | 1 x USB-C (umthengi) yolawulo lwengingqi |
Inethiwekhi ubungakanani - ubude of intambo
| Isibini esijijekileyo (TP) | 0-100 m |
| Ifayibha yemowudi enye (SM) 9/125 µm | jonga iimodyuli ze-SFP |
| Ifayibha yemowudi enye (LH) 9/125 µm (i-transceiver yokuthutha ixesha elide) | jonga iimodyuli ze-SFP |
| Ifayibha ye-Multimode (MM) 50/125 µm | jonga iimodyuli ze-SFP |
| Ifayibha ye-Multimode (MM) 62.5/125 µm | jonga iimodyuli ze-SFP |
Inethiwekhi ubungakanani - ukucasuka
| I-topology yomgca / inkwenkwezi | nayiphi na |
Amandla iimfuno
| I-Voltage yokusebenza | Igalelo lombane 1: 110 - 240 VAC, 50 Hz - 60 Hz, Igalelo lombane 2: 110 - 240 VAC, 50 Hz - 60 Hz |
| Ukutya umbane | Iyunithi esisiseko enombane omnye ophezulu. 35W |
| Ukuphuma kwamandla kwi-BTU (IT)/h | ubuninzi. 120 |
Isoftware
|
Ukutshintsha | Ukufunda kwe-VLAN okuZimeleyo, Ukuguga Okukhawulezayo, Ii-Static Unicast/Multicast Address Entries, I-QoS / Port Prioritization (802.1D/p), I-TOS/DSCP Prioritization, I-Interface Trust Mode, Ulawulo lwe-CoS Queue, Ukubumba i-Queue / Max. Queue Bandwidth, Ulawulo lokuhamba (802.3X), Ukubumba i-Egress Interface, Ukhuseleko lwe-Ingress Storm, Ii-Jumbo Frames, I-VLAN (802.1Q), I-VLAN Unware Mode, I-GARP VLAN Registration Protocol (GVRP), I-Voice VLAN, I-GARP Multicast Registration Protocol (GMRP), I-IGMP Snooping/Querier nge-VLAN (v1/v2/v3), Ukucoca i-Multicast engaziwayo, I-Multiple VLAN Registration Protocol (MVRP), I-Multiple MAC Registration Protocol (MMRP), I-Multiple Registration Protocol (MRP), I-IP Ingress DiffServ Classification and Policing, I-IP Egress DiffServ Classification and Policing, I-VLAN esekelwe kwi-Protocol, I-MAC-based VLAN, I-IP subnet-based VLAN, I-Double VLAN Tagging |
| Ukuphinda kusetyenziswe imali engakumbi | I-HIPER-Ring (iRing Switch), iLink Aggregation ne-LACP, iLink Backup, iMedia Redundancy Protocol (MRP) (IEC62439-2), iRSTP 802.1D-2004 (IEC62439-1), iiRSTP Guards |
| Ulawulo | Inkxaso yoMfanekiso weSoftware ezimbini, iTFTP, iSFTP, iSCP, iLLDP (802.1AB), iLLDP-MED, iSSHv2, iHTTP, iHTTPS, uLawulo lwe-IPv6, iiTraps, iSNMP v1/v2/v3, iTelnet, uMthengi weDNS, iSeva ye-OPC-UA |
| Uxilongo | Ulawulo lweDilesi yokuQondwa kweNgxabano, Isaziso seMAC, Uqhagamshelwano lweSignali, Isalathisi seMeko yeSixhobo, i-TCPDump, ii-LED, i-Syslog, ukuGcina i-ACA rhoqo, ukuJonga iPort ngokuZikhubaza ngokuzenzekelayo, ukuQonda iLink Flap, ukuQonda iOverload, ukuQonda iDuplex mismatch, iLink Speed kunye nokuJonga iDuplex, i-RMON (1,2,3,9), iPort Mirroring 1:1, iPort Mirroring 8:1, iPort Mirroring N:1, iPort Mirroring N:2, Ulwazi lweNkqubo, ukuZivavanya kwiCold Start, uVavanyo lweCopper Cable, uLawulo lwe-SFP, iConfiguration Check Dialog, iSwitch Dump, i-imeyile Isaziso, i-RSPAN, i-SFLOW, iVLAN Mirroring |
| Uqwalaselo | Uhlengahlengiso Loqwalaselo Oluzenzekelayo (ukujika umva), Uqwalaselo lweminwe yoqwalaselo, Ifayile yoqwalaselo olusekwe kumbhalo (XML), Uqwalaselo lwe-backup kwiseva ekude xa ugcina, Cima uqwalaselo kodwa ugcine useto lwe-IP, Iklayenti le-BOOTP/DHCP elinoqwalaselo oluzenzekelayo, Iseva ye-DHCP: ngePort, Iseva ye-DHCP: IiPools nge-VLAN, I-AutoConfiguration Adapter ACA31 (ikhadi le-SD), i-HiDiscovery, i-DHCP Relay ene-Option 82, i-Command Line Interface (CLI), i-CLI Scripting, ukuphathwa kweskripthi se-CLI phezu kwe-ENVM xa iqalisa, Inkxaso ye-MIB epheleleyo, Uncedo olusengqiqweni komxholo, Ulawulo olusekwe kwi-HTML5 |
|
Ukhuseleko | Ukhuseleko lweZibuko olusekwe kwi-MAC, Ulawulo lokufikelela olusekwe kwiZibuko olune-802.1X, i-VLAN yeNdwendwe/engaqinisekiswanga, iSeva yoQinisekiso oluDibeneyo (i-IAS), i-RADIUS VLAN Assignment, uThintelo lokuNqanda iNkonzo, i-ACL esekwe kwi-VLAN, i-ACL esekwe kwi-VLAN, i-ACL esisiseko, ukufikelela kuLawulo oluthintelweyo yi-VLAN, iSiboniso soKhuseleko lweSixhobo, uMzila woVavanyo, ukuLoga kwe-CLI, uLawulo lweSatifikethi se-HTTPS, ukufikelela kuLawulo oluNqamlelweyo, iBhana yoSetyenziso olufanelekileyo, uMgaqo-nkqubo wePhasiwedi oCwangcisiweyo, Inani eliQokelelweyo lemizamo yokungena, ukuLoga kwe-SNMP, amanqanaba amaninzi amalungelo, uLawulo lwaBasebenzisi beNdawo, uQinisekiso olukude nge-RADIUS, ukuLoga kwiAkhawunti yoMsebenzisi, utshintsho lwegama eligqithisiweyo ekungeneni kokuqala, i-RADIUS Policy Assignment, uQinisekiso lwabathengi abaninzi ngeZibuko ngalinye, i-MAC Authentication Bypass, iinketho zefomathi ye-MAC authentication bypass, i-DHCP Snooping, i-IP Source Guard, i-Dynamic ARP Inspection, i-LDAP, i-ACL esekwe kwi-MAC, i-ACL esekwe kwi-MAC, i-ACL esekwe kwi-MAC, i-ACL esekwe kwi-IPv4, i-ACL esekwe kwi-IPv4, i-ACL esekwe kwiXesha, i-ACL esekwe kwi-VLAN Ukunciphisa i-ACL, i-ACL flow-based Limits |
| Ukuvumelanisa ixesha | I-PTPv2 Transparent Clock enamanyathelo amabini, I-PTPv2 Boundary Clock, BC ene-Sync ukuya kuthi ga kwi-8 / s, I-Buffered Real Time Client, i-SNTP Client, i-SNTP Server |
| Iiprofayili zeShishini | Iprotokholi ye-Ethernet/IP Modbus TCP PROFINET Protokholi |
| Ezininzi | Ukuwela iintambo ngesandla, umbane wezibuko uphantsi |
Iimeko zemozulu
| Ubushushu bokusebenza | -10 - +60 |
| Phawula | 1 013 941 |
| Ubushushu bokugcina/bokuthutha | -20 - +70 °C |
| Ukufuma okuthelekisekayo (okungavuthisi) | 5-90% |
Ukwakhiwa koomatshini
| Ubukhulu (i-WxHxD) | 444 x 44 x 355 mm |
| Ubunzima | Kuqikelelwa i-5 kg |
| Ukufakelwa | Indawo yokuxhoma irekhi |
| Udidi lokhuseleko | IP30 |
Iimodeli zeHirschmann GRS 105 106 Series GREYHOUND Switch ezikhoyo
GRS105-16TX/14SFP-2HV-3AUR
GRS105-24TX/6SFP-1HV-2A
GRS105-24TX/6SFP-2HV-2A
GRS105-24TX/6SFP-2HV-3AUR
GRS106-16TX/14SFP-1HV-2A
GRS106-16TX/14SFP-2HV-2A
GRS106-16TX/14SFP-2HV-3AUR
GRS106-24TX/6SFP-1HV-2A
GRS106-24TX/6SFP-2HV-2A
GRS106-24TX/6SFP-2HV-3AUR
Iimveliso ezinxulumene noko
-
Iswitshi eNcinci yeHirschmann RS30-2402O6O6SDAE
Umhla woRhwebo Inkcazo yemveliso Inkcazo yeeport ezingama-26 I-Gigabit/Fast-Ethernet-Switch (2 x Gigabit Ethernet, 24 x Fast Ethernet), isoftware elawulwayo, Umaleko wesi-2 Ophuculweyo, wokutshintsha i-DIN rail-and-forward, uyilo olungenafeni Uhlobo lwezibuko kunye nobungakanani Iiport ezingama-26 zizonke, iiport ezi-2 ze-Gigabit Ethernet; 1. i-uplink: I-Gigabit SFP-Slot; 2. i-uplink: I-Gigabit SFP-Slot; 24 x standard 10/100 BASE TX, RJ45 Okunye Unxibelelwano Umbane/uqhagamshelwano lokubonisana ...
-
Hirschmann SPIDER-SL-40-08T1999999SY9HHHH Unman...
Inkcazo yemveliso Imveliso: SSR40-8TX Isilungisi: SSR40-8TX Inkcazo yemveliso Uhlobo SSR40-8TX (Ikhowudi yemveliso: SPIDER-SL-40-08T1999999SY9HHHH ) Inkcazo Ayilawulwa, Iswitshi yesitimela ye-Ethernet yezeMveliso, uyilo olungenafeni, imo yokutshintsha yokugcina kunye neyokuya phambili, I-Ethernet epheleleyo yeGigabit, Inombolo yeCandelo leGigabit epheleleyo yeEthernet 942335004 Uhlobo lwezibuko kunye nobungakanani 8 x 10/100/1000BASE-T, intambo ye-TP, amasokhethi e-RJ45, ukunqumla ngokuzenzekelayo, ukuxoxisana ngokuzenzekelayo,...
-
I-Hirschmann M-SFP-LX+/LC SFP Transceiver
Umhla woRhwebo Inkcazo yemveliso Uhlobo: M-SFP-LX+/LC, SFP Transceiver Inkcazo: SFP Fiberoptic Gigabit Ethernet Transceiver SM Inombolo yeCandelo: 942023001 Uhlobo lwezibuko kunye nobungakanani: 1 x 1000 Mbit/s ene-LC connector Ubungakanani benethiwekhi - ubude bentambo Ifayibha yemowudi enye (SM) 9/125 µm: 14 - 42 km (Uhlahlo lwabiwo-mali lwekhonkco kwi-1310 nm = 5 - 20 dB; A = 0,4 dB/km; D = 3,5 ps/(nm*km)) Iimfuno zamandla...
-
Iswitshi yeHirschmann BRS40-0020OOOO-STCZ99HHSES
Inkcazo ye-Commerial Date Configurator I-Hirschmann BOBCAT Switch yeyokuqala yohlobo lwayo ukuvumela unxibelelwano lwexesha langempela kusetyenziswa i-TSN. Ukuxhasa ngempumelelo iimfuno zonxibelelwano zexesha langempela ezikhulayo kwiindawo zoshishino, umqolo wenethiwekhi ye-Ethernet oqinileyo ubalulekile. Ezi switshi ezilawulwayo ezincinci zivumela amandla e-bandwidth akhulisiweyo ngokulungelelanisa ii-SFP zakho ukusuka kwi-1 ukuya kwi-2.5 Gigabit - akufuneki tshintsho kwisicelo...
-
Hirschmann OS20-000800T5T5T5-TBBU999HHHE2S Tshintsha
Inkcazo yemveliso Imveliso: OS20-000800T5T5T5-TBBU999HHHE2SXX.X.XX Isicwangcisi: OS20/24/30/34 - Isicwangcisi se-OCTOPUS II Yenzelwe ngokukodwa ukusetyenziswa kwinqanaba lentsimi kunye neenethiwekhi zokwenza izinto ngokuzenzekelayo, iiswitshi kusapho lwe-OCTOPUS ziqinisekisa amazinga aphezulu okhuseleko lwemizi-mveliso (IP67, IP65 okanye IP54) malunga noxinzelelo loomatshini, ukufuma, ukungcola, uthuli, ukutshayiswa kunye nokungcangcazela. Ziyakwazi ukumelana nobushushu nokubanda,...
-
Hirschmann GRS1030-16T9SMMZ9HHSE2S Tshintshela
Imveliso Yentshayelelo: GRS1030-16T9SMZ9HHSE2SXX.X.XX Isicwangcisi: GREYHOUND 1020/30 Isicwangcisi seSwitch Inkcazo yemveliso Inkcazo Isicwangcisi se-Ethernet esilawulwa yimizi-mveliso esikhawulezayo, esifakwe kwi-Gigabit, esifakelwe kwi-rack eyi-19", esingenafeni Uyilo ngokwe-IEEE 802.3, iSoftware yokutshintsha yokugcina nokuthumela phambili inguqulelo ye-HiOS 07.1.08 Uhlobo lwePort kunye nobungakanani IiPorts zizonke ukuya kuthi ga kwi-28 x 4 Fast Ethernet, iiGigabit Ethernet Combo ports; Iyunithi esisiseko: 4 FE, GE a...