• ibhena_yentloko_01

I-MOXA NPort 5232 ii-port ezimbini ze-RS-422/485 Iseva yeSixhobo seSerial seZinto zeShishini

Inkcazo emfutshane:

Iiseva ze-NPort5200 zezixhobo ze-serial zenzelwe ukwenza izixhobo zakho ze-serial ze-industrial zilungele i-intanethi ngokukhawuleza. Ubungakanani obuncinci beeseva ze-serial ze-NPort 5200 zezixhobo ze-serial buzenza zibe lolona khetho lufanelekileyo lokudibanisa izixhobo zakho ze-RS-232 (NPort 5210/5230/5210-T/5230-T) okanye i-RS-422/485 (NPort 5230/5232/5232I/5230-T/5232-T/5232I-T) ze-serial—ezifana nee-PLC, iimitha, kunye nee-sensors—kwi-IP-based Ethernet LAN, okwenza kube nokwenzeka ukuba isoftware yakho ifikelele kwizixhobo ze-serial ukusuka naphi na nge-LAN yasekuhlaleni okanye kwi-Intanethi. I-NPort 5200 Series ineempawu ezininzi eziluncedo, kubandakanya iiprotokholi ze-TCP/IP eziqhelekileyo kunye neendlela zokusebenza ezikhethiweyo, abaqhubi be-Real COM/TTY kwisoftware ekhoyo, kunye nolawulo olukude lwezixhobo ze-serial nge-TCP/IP okanye i-COM/TTY Port yendabuko.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Iimpawu kunye neenzuzo

Uyilo oluncinci ukuze kube lula ukuyifaka

Iindlela zeSocket: Iseva yeTCP, umxhasi weTCP, i-UDP

Isixhobo seWindows esilula ukusisebenzisa sokulungiselela iiseva zezixhobo ezininzi

I-ADDC (Ulawulo lweDatha oluZenzekelayo) lwe-RS-485 enezintambo ezimbini kunye nezintambo ezine

I-SNMP MIB-II yolawulo lwenethiwekhi

Iinkcukacha

 

Ujongano lwe-Ethernet

Iiports ze-10/100BaseT(X) (isixhumi se-RJ45) 1
Ukhuseleko lokuZihlukanisa ngeMagnetic  1.5 kV (eyakhelwe ngaphakathi)

 

 

Iimpawu zeSoftware ye-Ethernet

Iinketho zoBumbeko

Utility lweWindows, iTelnet Console, iWeb Console (HTTP), iSerial Console

Ulawulo Umxhasi we-DHCP, IPv4, SNTP, SMTP, SNMPv1, DNS, HTTP, ARP, BOOTP, UDP, TCP/IP, Telnet, ICMP
Abaqhubi beWindows Real COM

IiWindows 95/98/ME/NT/2000, iiWindows XP/2003/Vista/2008/7/8/8.1/10/11 (x86/x64),

IWindows 2008 R2/2012/2012 R2/2016/2019 (x64), iWindows Server 2022, iWindows Embedded CE 5.0/6.0, iWindows XP Embedded

Abaqhubi beTTY abaQinisekisiweyo I-SCO UNIX, i-SCO OpenServer, i-UnixWare 7, i-QNX 4.25, i-QNX 6, i-Solaris 10, i-FreeBSD, i-AIX 5. x, i-HP-UX 11i, i-Mac OS X, i-macOS 10.12, i-macOS 10.13, i-macOS 10.14, i-macOS 10.15
Abaqhubi beLinux Real TTY Iinguqulelo zeKernel: 2.4.x, 2.6.x, 3.x, 4.x, kunye ne-5.x
I-API ye-Android I-Android 3.1.x kunye neyamva
I-MIB RFC1213, RFC1317

 

Iiparameters zamandla

Igalelo langoku Iimodeli ze-NPort 5210/5230: 325 mA@12 VDCIimodeli ze-NPort 5232/5232I: 280 mA@12 VDC, 365 mA@12 VDC
I-Voltage yokufaka 12ukuya ku-48 VDC
Inani lee-Power Inputs 1
Isixhumi samandla Ibhloko enye (iibhloko) yesiphelo esinoqhagamshelwano olu-3 esuswayo e-1

  

Iimpawu zomzimba

Izindlu Isinyithi
Ubukhulu (neendlebe) Iimodeli ze-NPort 5210/5230/5232/5232-T: 90 x 100.4 x 22 mm (3.54 x 3.95 x 0.87 in)Iimodeli ze-NPort 5232I/5232I-T: 90 x100.4 x 35 mm (3.54 x 3.95 x 1.37 in)
Ubukhulu (ngaphandle kweendlebe) Iimodeli ze-NPort 5210/5230/5232/5232-T: 67 x 100.4 x 22 mm (2.64 x 3.95 x 0.87 in)I-NPort 5232I/5232I-T: 67 x 100.4 x 35 mm (2.64 x 3.95 x 1.37 in)
Ubunzima Iimodeli ze-NPort 5210: 340 g (0.75 lb)Iimodeli ze-NPort 5230/5232/5232-T: 360 g (0.79 lb)Iimodeli ze-NPort 5232I/5232I-T: 380 g (0.84 lb)
Ufakelo Idesktop, ukufakwa kwe-DIN-rail (kunye nekhithi yokuzikhethela), ukufakwa eludongeni

 

Imida yokusingqongileyo

Ubushushu bokusebenza Iimodeli eziQhelekileyo: 0 ukuya kuma-55°C (32 ukuya kuma-131°F)Iimodeli zobushushu obubanzi: -40 ukuya kwi-75°C (-40 ukuya kwi-167°F)
Ubushushu bokugcina (kuqukiwe iphakheji) -40 ukuya kwi-75°C (-40 ukuya kwi-167°F)
Umswakama oqhelekileyo kwindawo 5 ukuya kwi-95% (ayifumi)

 

Iimodeli ezikhoyo ze-MOXA NPort 5232

Igama lomzekelo

Ubushushu bokusebenza.

I-Baudrate

Imigangatho yoBuchule

Ukuzahlula ngokulandelelana

Inani leePorts eziNqamlezileyo

I-Voltage yokufaka

I-NPort 5210

0 ukuya kuma-55°C

110 bps ukuya kwi-230.4 kbps

I-RS-232

-

2

12-48 VDC

I-NPort 5210-T

-40 ukuya kwi-75°C

110 bps ukuya kwi-230.4 kbps

I-RS-232

-

2

12-48 VDC

I-NPort 5230

0 ukuya kuma-55°C

110 bps ukuya kwi-230.4 kbps

I-RS-232/422/485

-

2

12-48 VDC
I-NPort 5230-T

-40 ukuya kwi-75°C

110 bps ukuya kwi-230.4 kbps

I-RS-232/422/485

-

2

12-48 VDC
I-NPort 5232

0 ukuya kuma-55°C

110 bps ukuya kwi-230.4 kbps

I-RS-422/485

-

2

12-48 VDC
I-NPort 5232-T

-40 ukuya kwi-75°C

110 bps ukuya kwi-230.4 kbps

I-RS-422/485

-

2

12-48 VDC

I-NPort 5232I

0 ukuya kuma-55°C

110 bps ukuya kwi-230.4 kbps

I-RS-422/485

2kV

2

12-48 VDC

I-NPort 5232I-T

-40 ukuya kwi-75°C

110 bps ukuya kwi-230.4 kbps

I-RS-422/485

2kV

2

12-48 VDC

 


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha uze uwuthumele kuthi

    Iimveliso ezinxulumene noko

    • I-MOXA IMC-21A-M-SC Industrial Media Converter

      I-MOXA IMC-21A-M-SC Industrial Media Converter

      Iimpawu kunye neeNzuzo Imowudi ezininzi okanye enye, ene-SC okanye i-ST fiber connector I-Link Fault Pass-Through (LFTT) -40 ukuya kwi-75°C ubushushu bokusebenza (iimodeli ze--T) Iiswitshi ze-DIP zokukhetha i-FDX/HDX/10/100/Auto/Force Specifications I-Ethernet Interface 10/100BaseT(X) Ports (i-RJ45 connector) 1 100BaseFX Ports (imowudi ezininzi SC conn...

    • I-MOXA DE-311 Umncedisi weSixhobo ngokuBanzi

      I-MOXA DE-311 Umncedisi weSixhobo ngokuBanzi

      Intshayelelo I-NPortDE-211 kunye ne-DE-311 ziiseva zesixhobo esi-serial esine-port enye ezixhasa i-RS-232, RS-422, kunye ne-2-wire RS-485. I-DE-211 ixhasa uqhagamshelo lwe-Ethernet lwe-10 Mbps kwaye inesixhumi se-Ethernet se-DB25 esibhinqileyo kwi-serial port. I-DE-311 ixhasa uqhagamshelo lwe-Ethernet lwe-10/100 Mbps kwaye inesixhumi se-DB9 esibhinqileyo kwi-serial port. Zombini iiseva zesixhobo zilungele usetyenziso olubandakanya iibhodi zokubonisa ulwazi, ii-PLC, iimitha zokuhamba, iimitha zegesi,...

    • I-MOXA IKS-6728A-8PoE-4GTXSFP-HV-T I-Modular Managed PoE Industrial Ethernet Switch

      Ulawulo lweModular lweMOXA IKS-6728A-8PoE-4GTXSFP-HV-T...

      Iimpawu kunye neeNzuzo Iiports zePoE+ ezi-8 ezakhelwe ngaphakathi zihambelana ne-IEEE 802.3af/at (IKS-6728A-8PoE) Ukuphuma okufikelela kwi-36 W ngeport nganye yePoE+ (IKS-6728A-8PoE) I-Turbo Ring kunye neTurbo Chain (ixesha lokubuyisela kwimeko yesiqhelo).< 20 ms @ 250 switches) , kunye ne-STP/RSTP/MSTP yokusetyenziswa kwakhona kwenethiwekhi Ukhuseleko lwe-1 kV LAN surge kwiindawo ezingaphandle ezigqithisileyo Ukuxilongwa kwe-PoE kohlalutyo lwemo yesixhobo esinikwe amandla Iiports ezi-4 ze-Gigabit combo zonxibelelwano oluphezulu...

    • Iswitshi ye-Ethernet engalawulwayo ye-MOXA EDS-305-S-SC enezibuko ezi-5

      Iswitshi ye-Ethernet engalawulwayo ye-MOXA EDS-305-S-SC enezibuko ezi-5

      Intshayelelo Iiswitshi ze-EDS-305 Ethernet zibonelela ngesisombululo esingabizi kakhulu kwiintambo zakho ze-Ethernet zoshishino. Ezi switshi ze-5-port ziza nomsebenzi wesilumkiso se-relay esakhelwe ngaphakathi esilumkisa iinjineli zenethiwekhi xa umbane ungasebenzi okanye ii-port ziqhekeka. Ukongeza, ezi switshi zenzelwe iindawo ezinzima zoshishino, njengeendawo ezinobungozi ezichazwe yimigangatho yeClass 1 Div. 2 kunye ne-ATEX Zone 2. Iiswitshi ...

    • I-MOXA EDS-516A-MM-SC enezibuko ezili-16 zoLawulo lwe-Ethernet yoShishino

      I-MOXA EDS-516A-MM-SC I-16-port eLawulwayo yoShishino ...

      Iimpawu kunye neenzuzo I-Turbo Ring kunye neTurbo Chain (ixesha lokubuyisela < 20 ms @ 250 switches), kunye ne-STP/RSTP/MSTP yokuphinda usebenzise inethiwekhi i-TACACS+, i-SNMPv3, i-IEEE 802.1X, i-HTTPS, kunye ne-SSH ukuphucula ukhuseleko lwenethiwekhi Ulawulo lwenethiwekhi olulula ngesikhangeli sewebhu, i-CLI, i-Telnet/serial console, utility yeWindows, kunye ne-ABC-01 Ixhasa i-MXstudio kulawulo lwenethiwekhi yemizi-mveliso olulula nolubonakalayo ...

    • Iseva yeSixhobo seSerial se-MOXA NPort 5410 seZimbiwa

      Isixhobo seSerial se-MOXA NPort 5410 seZimbiwa Jikelele...

      Iimpawu kunye neenzuzo Iphaneli ye-LCD esebenziseka lula ukuyisebenzisa ukuze kube lula ukuyifakela Izithinteli ezihlengahlengiswayo zokuphelisa kunye nokutsala eziphezulu/ezisezantsi Iindlela zesokhethi: Iseva ye-TCP, iklayenti le-TCP, i-UDP Configuration yiTelnet, isikhangeli sewebhu, okanye isixhobo seWindows SNMP MIB-II yolawulo lwenethiwekhi Ukhuseleko lokwahlulwa kwe-2 kV kwi-NPort 5430I/5450I/5450I-T -40 ukuya kwi-75°C uluhlu lobushushu bokusebenza (imodeli ye--T) Inkcazo...